| 66kV油浸式三相双绕组无励磁调压电力变压器 | |||||||||||
| 额定容量 kVA | 电压组合及分接范围 | 联结组标号 | 1级 | 2级 | 3级 | 短路阻抗 % | |||||
| 空载损耗 kW | 负载损耗 kW | 空载损耗 kW | 负载损耗 kW | 空载损耗 kW | 负载损耗 kW | ||||||
| 3 150 | 63 66 69 | ±5 | 6.3 6.6 10.5 | YNd11 | 2.2 | 20.7 | 2.6 | 20.7 | 3.2 | 21.9 | 8 |
| 4 000 | 2.6 | 24.6 | 3.1 | 24.6 | 3.8 | 25.9 | |||||
| 5 000 | 3.1 | 27.6 | 3.7 | 27.6 | 4.6 | 29.2 | |||||
| 6 300 | ±2×2.5 | 4.0 | 30.8 | 4.7 | 30.8 | 5.8 | 32.5 | 9 | |||
| 8 000 | 4.9 | 36.5 | 5.8 | 36.5 | 7.1 | 38.5 | |||||
| 10 000 | 5.8 | 43 | 6.8 | 43 | 8.4 | 45.4 | |||||
| 12 500 | 6.8 | 51.1 | 8.1 | 51.1 | 9.9 | 54 | |||||
| 16 000 | 8.3 | 62.8 | 9.8 | 62.8 | 12 | 66.3 | |||||
| 20 000 | 9.7 | 76.1 | 11.4 | 76.1 | 14.1 | 80.4 | |||||
| 25 000 | 11.4 | 90 | 13.5 | 90 | 16.6 | 95 | |||||
| 31 500 | 13.5 | 108 | 16 | 108 | 19.7 | 114 | |||||
| 40 000 | 16.2 | 126.9 | 19.1 | 126.9 | 23.5 | 134 | |||||
| 50 000 | 19.4 | 150.3 | 22.9 | 150.3 | 28.2 | 158.7 | |||||
| 63 000 | 22.9 | 178.2 | 27 | 178.2 | 33.3 | 188.1 | |||||
| 66kV油浸式三相双绕组有载调压电力变压器 | |||||||||||
| 额定容量 kVA | 电压组合及分接范围 | 联结组标号 | 1级 | 2级 | 3级 | 短路阻抗 % | |||||
| 空载损耗 kW | 负载损耗 kW | 空载损耗 kW | 负载损耗 kW | 空载损耗 kW | 负载损耗 kW | ||||||
| 6 300 | 63 66 69 | ±4×1.25 ±6×1.25 ±8×1.25 | 6.3 6.6 10.5 | YNd11 | 4.4 | 30.8 | 5.2 | 30.8 | 6.4 | 32.5 | 9~12 |
| 8 000 | 5.3 | 36.5 | 6.2 | 36.5 | 7.7 | 38.5 | |||||
| 10 000 | 6.2 | 43.0 | 7.3 | 43.0 | 9.0 | 45.4 | |||||
| 12 500 | 7.4 | 51.1 | 8.7 | 51.1 | 10.7 | 54.0 | |||||
| 16 000 | 8.9 | 62.8 | 10.5 | 62.8 | 12.9 | 66.3 | |||||
| 20 000 | 10.6 | 76.1 | 12.5 | 76.1 | 15.4 | 80.4 | |||||
| 25 000 | 12.5 | 90.0 | 14.8 | 90.0 | 18.2 | 95.0 | |||||
| 31 500 | 14.8 | 108.0 | 17.5 | 108.0 | 21.5 | 114.0 | |||||
| 40 000 | 17.7 | 126.9 | 20.9 | 126.9 | 25.8 | 134.0 | |||||
| 50 000 | 20.9 | 150.3 | 24.7 | 150.3 | 30.4 | 158.7 | |||||
| 63 000 | 24.7 | 178.2 | 29.2 | 178.2 | 35.9 | 188.1 | |||||
| 110 kV 油浸式三相三绕组有载调压电力变压器 | ||||||||||||||
| 额定容量 kVA | 电压组合及分接范围 | 联结组标号 | 1级 | 2级 | 3级 | 空载电流 % | 短路阻抗 % | |||||||
| 空载损耗 kW | 负载损耗 kW | 空载损耗 kW | 负载损耗 kW | 空载损耗 kW | 负载损耗 kW | |||||||||
| 6300 | 110 | ±4×1.25 ±6×1.25 ±8×1.25 | 36 37 38.5 | 6.3 6.6 10.5 21 | YNyn0d11 | 5.3 | 40 | 6.2 | 40 | 7.7 | 42 | 0.61 | 高-中10.5 高-低17.5-18.5 中-低6.5 | |
| 8000 | 6.3 | 48 | 7.5 | 48 | 9.2 | 50 | 0.61 | |||||||
| 10000 | 7.5 | 56 | 8.8 | 56 | 10.9 | 59 | 0.57 | |||||||
| 12500 | 8.9 | 67 | 10.5 | 67 | 12.9 | 70 | 0.57 | |||||||
| 16000 | 10.6 | 81 | 12.5 | 81 | 15.4 | 86 | 0.54 | |||||||
| 20000 | 12.5 | 95 | 14.8 | 95 | 18.2 | 101 | 0.54 | |||||||
| 25000 | 14.9 | 113 | 17.6 | 113 | 21.6 | 120 | 0.5 | |||||||
| 31500 | 17.7 | 134 | 20.9 | 134 | 25.7 | 142 | 0.5 | |||||||
| 40000 | 21.2 | 161 | 25 | 161 | 30.8 | 170 | 0.46 | |||||||
| 50000 | 25 | 192 | 29.6 | 192 | 36.4 | 202 | 0.46 | |||||||
| 63000 | 29.8 | 230 | 35.2 | 230 | 43.3 | 243 | 0.42 | |||||||
| 110 kV 油浸式三相双绕组有载调压电力变压器 | ||||||||||||
| 额定容量 kVA | 电压组合及分接范围 | 联结组标号 | 1级 | 2级 | 3级 | 空载电流 % | 短路阻抗 % | |||||
| 空载损耗 kW | 负载损耗 kW | 空载损耗 kW | 负载损耗 kW | 空载损耗 kW | 负载损耗 kW | |||||||
| 6300 | 110 | ±4×1.25 ±6×1.25 ±8×1.25 | 6.3 6.6 10.5 21 | YNd11 | 4.4 | 32 | 5.2 | 32 | 6.4 | 33 | 0.51 | 10.5 |
| 8000 | 5.3 | 38 | 6.2 | 38 | 7.7 | 40 | 0.51 | |||||
| 10000 | 6.2 | 45 | 7.3 | 45 | 9 | 48 | 0.47 | |||||
| 12500 | 7.4 | 53 | 8.7 | 53 | 10.7 | 56 | 0.47 | |||||
| 16000 | 8.9 | 66 | 10.5 | 66 | 12.9 | 69 | 0.44 | |||||
| 20000 | 10.6 | 79 | 12.5 | 79 | 15.4 | 84 | 0.44 | |||||
| 25000 | 12.5 | 94 | 14.8 | 94 | 18.2 | 99 | 0.41 | |||||
| 31500 | 14.9 | 111 | 17.6 | 111 | 21.6 | 117 | 0.41 | |||||
| 40000 | 17.8 | 140 | 21 | 140 | 25.8 | 148 | 0.37 | |||||
| 50000 | 21 | 175 | 24.8 | 175 | 30.6 | 184 | 0.37 | |||||
| 63000 | 25 | 209 | 29.5 | 209 | 36.3 | 220 | 0.34 | |||||